Evaluation of immediate complications in the placement of infrazygomatic microimplants
DOI:
https://doi.org/10.35381/s.v.v8i2.4271Keywords:
Laboratories dental, dental prosthesis, dental implants, (Source: DeCS)Abstract
Objective: To analyze the immediate complications in the placement of infrazygomatic microimplants to improve clinical protocols and reduce adverse events. Methods: A literature review was performed in databases between March 2013 and March 2023, using specific terms and Boolean operators to evaluate the frequency and severity of complications. Results: The success of infrazygomatic microimplants varies according to the insertion technique and anatomical characteristics of the patient. Complications include fractures, displacements, and injuries to anatomic structures. Conclusions: Detailed anatomic evaluation and adaptation of evidence-based protocols is essential to minimize risks. Further research is recommended to develop customized practices and improve the success rate of microimplant placement.
Downloads
References
Bungău TC, Vaida LL, Moca AE, Ciavoi G, Iurcov R, Romanul IM, Buhaș CL. Mini-implant rejection rate in teenage patients depending on insertion site: A retrospective study. Journal of Clinical Medicine. 2022;11(18). https://doi.org/10.3390/jcm11185331
Giudice AL, Rustico L, Longo M, Oteri G, Papadopoulos MA, Nucera R. Complications reported with the use of orthodontic miniscrews: A systematic review. Korean Journal of Orthodontics. 2021;51(3):199-216. https://doi.org/10.4041/KJOD.2021.51.3.199
Truong VM, Kim S, Kim J, Lee JW, Park YS. Revisiting the complications of orthodontic miniscrew. In BioMed Research International. 2022;1. https://doi.org/10.1155/2022/8720412
Murugesan A, Jain RK. A 3D comparison of dimension of infrazygomatic crest region in different vertical skeletal patterns: A retrospective study. International Orthodontics. 2020;18(4):770-775. https://doi.org/10.1016/j.ortho.2020.09.002
Paul P, Mathur AK, Chitra P. Cone beam computed tomographic comparison of infrazygomatic crest bone thickness in patients with different facial types. Orthodontic Waves. 2020;79(2):99-104. https://doi.org/10.1080/13440241.2020.1814523
Jia X, Chen X, Huang X. Influence of orthodontic mini-implant penetration of the maxillary sinus in the infrazygomatic crest region. American Journal of Orthodontics and Dentofacial Orthopedics. 2018;153(5):656-661. https://doi.org/10.1016/j.ajodo.2017.08.021
Du B, Zhu J, Li L, Fan T, Tan J, Li J. Bone depth and thickness of different infrazygomatic crest miniscrew insertion paths between the first and second maxillary molars for distal tooth movement: A 3-dimensional assessment. American Journal of Orthodontics and Dentofacial Orthopedics. 2021;160(1):113-123. https://doi.org/10.1016/j.ajodo.2020.03.036
Tavares A, Crusoé Rebello IM, Neves FS. Tomographic evaluation of infrazygomatic crest for orthodontic anchorage in different vertical and sagittal skeletal patterns. Journal of Clinical and Experimental Dentistry. 2020;12(11):1015-1020. https://doi.org/10.4317/jced.57267
Uribe F, Mehr R, Mathur A, Janakiraman N, Allareddy V. Failure rates of mini-implants placed in the infrazygomatic region. Progress in Orthodontics. 2015;16(31). https://doi.org/10.1186/s40510-015-0100-2
Gill G, Shashidhar K, Kuttappa MN, Kushalappa PBD, Sivamurthy G, Mallick S. Failure rates and factors associated with infrazygomatic crestal orthodontic implants - A prospective study. Journal of Oral Biology and Craniofacial Research. 2023;13(2):283-289. https://doi.org/10.1016/j.jobcr.2023.02.010
Pan Y, Wei L, Zheng Z, Bi W. An evaluation of bone depth at different three-dimensional paths in infrazygomatic crest region for miniscrew insertion: A cone beam computed tomography study. Heliyon. 2024;10(3). https://doi.org/10.1016/j.heliyon.2024.e25827
Sreenivasagan S, Subramanian AK, Selvaraj A, Marya A. Pain perception associated with mini-implants and interventions for pain management: A cross-sectional questionnaire-based survey. BioMed Research International. 2021;1-9. https://doi.org/10.1155/2021/4842865
Motoyoshi M, Sanuki Suzuki R, Uchida Y, Saiki A, Shimizu N. Maxillary sinus perforation by orthodontic anchor screws. Journal of Oral Science. 2015;57(2):95-100. https://doi.org/10.2334/josnusd.57.95
Golshah A, Gorji K, Nikkerdar N. Effect of miniscrew insertion angle in the maxillary buccal plate on its clinical survival: a randomized clinical trial. Progress in Orthodontics. 2021;22(22):1-9. https://doi.org/10.1186/s40510-021-00370-8
Paul P, Mathur AK, Chitra P. Stress distribution patterns in mini-implant and bone in the infra-zygomatic crest region at different angulations: A finite element study. Journal of the World Federation of Orthodontists. 2021;10(1):29-34. https://doi.org/10.1016/j.ejwf.2020.11.004
Su L, Song H, Huang X. Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study. BMC Oral Health. 2022;22(1). https://doi.org/10.1186/s12903-022-02285-0
Chang CH, Lin JS, Roberts WE. Failure rates for stainless steel versus titanium alloy infrazygomatic crest bone screws: A single-center, randomized double-blind clinical trial. Angle Orthodontist. 2019;89(1):40-46. https://doi.org/10.2319/012518-70.1
Kalra S, Tripathi T, Rai P, Kanase A. Evaluation of orthodontic mini-implant placement: A CBCT study. Progress in Orthodontics. 2014;15(61):1-9. https://doi.org/10.1186/s40510-014-0061-x
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Mónica Tatiana Siguencia-Avila, Christian David Zapata-Hidalgo, Vinicio Egidio Barzallo-Sardi

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
CC BY-NC-SA : Esta licencia permite a los reutilizadores distribuir, remezclar, adaptar y construir sobre el material en cualquier medio o formato solo con fines no comerciales, y solo siempre y cuando se dé la atribución al creador. Si remezcla, adapta o construye sobre el material, debe licenciar el material modificado bajo términos idénticos.
OAI-PMH: https://fundacionkoinonia.com.ve/ojs/index.php/saludyvida/oai.